Vertical H-Frame Adjustable Electromagnet Description
The vertical H-Frame adjustable electromagnet has a magnetic field air gap adjustable unidirectionally, a double yoke structure that forms a closed magnetic circuit with good rigidity, and a vertical magnetic field direction. A sample can also be placed on the lower pole plane for convenience. The vertical H-frame adjustable electromagnet is widely used in Hall effect research, magnetoresistance effect research, and magnetic hysteresis retractable research. The vertical H-Frame adjustable electromagnet can also be used as a torque magnetometer, force method magnetometer, magnetic susceptibility measurement device, magnetic material measurement device, and magnetizer and demagnetizer of magnetic devices. In order to increase the magnetic field strength, the electromagnet can also be equipped with a ferroalloy pole, which can process even magnetic field poles, gradient magnetic field poles, electromagnet rotary tables, electromagnet shields, electromagnet supporting bases, undercarriages, and bottom boxes.
H-Frame Adjustable Electromagnet Diagram
Vertical-Frame Adjustable Electromagnet Dimensions
Vertical-Frame Adjustable Electromagnet Specifications
Vertical-Frame Adjustable Electromagnet Details
The electromagnet is a double yoke monotonous type with an upright seat
The pole unidirectionally adjusts the variable air gap
The magnetic field direction is perpendicular to the ground
The diameter of the electromagnet pole is 130, and a pole with a diameter of 60mm is provided
The spacing between the coils is 120mm
The air gap is adjustable from 0 to 100mm
When the air gap is 10mm, the magnetic field H ≥ 2.6T
Inner cooling structure
When the magnetic pole spacing is 25mm, the electromagnet can produce a 1.7T magnetic field with a working time of 30 minutes
Scanning magnetic field can work for a long time
When the air gap is 15mm, the magnetic field uniformity in the central 10*10*10mm³ area is better than 0.1%
Line resistance: 5.0 ohms with rated power supply of 3.0kw
Power supply: 30A, 150V
VHP-130
VHP-200
The electromagnet is a double yoke monotonous type with an upright seat
The pole unidirectionally adjusts the variable air gap
The magnetic field direction is perpendicular to the ground
The diameter of the electromagnet pole is 200mm
The diameter of the pole head is 80mm
The spacing between the coils is 120mm
The air gap is adjustable from 0 to 100mm
When the air gap is 10mm, the magnetic field H ≥ 2.8T
Inner cooling structure
When the magnetic pole spacing is 30mm, the electromagnet can produce a 2.3T magnetic field with a working time of 10 minutes
Scanning magnetic field can work for a long time.
When the air gap is 20mm, the magnetic field uniformity in the central 10*10*10mm³ area is better than 0.1%
Wire package resistance of 5.0 ohms, rated for power supply of 8.0kw
Power supply: 50A, 240V
The electromagnet is a double yoke monotonous type with an upright seat
The poles are unidirectionally adjusts the variable air gap
The magnetic field direction is perpendicular to the ground
The diameter of the electromagnet pole is 250mm
The diameter of the pole head is 120mm
The spacing between the coils is 120mm
The air gap is adjustable from 0 to 100mm
When the air gap is 10mm, the magnetic field H ≥ 2.6T
Inner water cooling structure
When the magnetic pole spacing is 30mm, the electromagnet can produce a 2.2T magnetic field with a working time of 10 minutes
Scanning magnetic field can work for a long time
When the air gap is 20mm, the magnetic field uniformity in the central 20*20*20mm³ area is better than 0.1%
Wire package resistance of 5.0 ohms, rated for power supply of 10.0kw
Power supply: 50A, 240V
VHP-250