H-Frame Adjustable Electromagnet Description
The H-Frame adjustable electromagnet has a magnetic field air gap adjustable bidirectionally and a double yoke structure that forms a closed magnetic circuit with good rigidity. The yoke is inclined at an angle of 45 degrees to facilitate the taking and placing of samples and other equipment. The H-frame adjustable electromagnet has a horizontal magnetic field direction. H-Frame adjustable electromagnets have a wide range of air gap adjustment and feature easy pole replacement. They are suitable for Hall effect research, magnetoresistance effect research, hysteresis retraction studies, torque magnetometers, force method magnetometers, vibration sample magnetometers, etc. In addition, H-frame adjustable electromagnets are also capable magnetic susceptibility and magnetic material measuring devices.
H-Frame Adjustable Electromagnet Diagram
H-Frame Adjustable Electromagnet Dimensions
H-Frame Adjustable Electromagnet Specifications
H-Frame Adjustable Electromagnet Details
The electromagnet is a double yoke type frame structure inclined at a 45 degree angle
The magnetic field is in the horizontal direction
The pole diameter is 80mm
The spacing between the cables is 100mm
The magnetic air gap is adjustable in both directions from 0-100mm
The electromagnet is equipped with a payable pole with pole diameter 80mm
When the air gap is 40mm, the central magnetic field Hmax≥0.5T
Pole head aperture width: 5mm
When the air gap is 40mm the electromagnet can provide a continuous 0.4T magnetic field environment for 1 hour
External dimensions: 440*450*360 mm³
Weight: 100kg
Power supply: 10A, 60V
HP-80
HP-100
The electromagnet has a double yoke and modulating structure, and it is placed obliquely at 45 degrees
The direction of the magnetic field is horizontal to the ground
The diameter of the pole is 100mm
The spacing between the coils is 100mm
The adjustable range of the air gap is from 0-100mm
When the air gap is 10mm, the central magnetic field Hmax≥1.5T
When the air gap is 80mm, the central magnetic field Hmax≥0.4T
In the centerral 5*5*5mm³ area, the magnetic field uniformity is 1*10e-5
The electromagnet is naturally cooled
When the air gap is 80mm the electromagnet can provide a continuous 0.4T magnetic field environment for 0.5 hours
Weight: 200kg
Power supply: 10A, 120V
The electromagnet is a double yoke type frame structure inclined at a 45 degree angle
The magnetic field is in the horizontal direction
The pole diameter is 250mm
The spacing between the cables is 120mm
The magnetic air gap is adjustable in both directions from 20~120mm
The electromagnet is equipped with a payable pole with diameter 70mm
When the air gap is 50mm, the center magnetic field Hmax≥2.1T;
Internal water cooling structure
When the air gap is 50mm the electromagnet can provide a continuous 2.1T magnetic field environment for 0.5 hours
Weight: 2200kg
Power supply: 75A, 180V
HP-250